🕔 Call For Paper — Vol. 12  |  Issue 4  |  December 2026  |  Deadline: 20-Dec-2026
Track Paper Submit Paper Contact

Paper Details

Home › Archives › Paper Details
← Back to Issue
Vol. 5  No. 3 (2019) · Articles

OPTIMISING THE SLUMP IN CONCRETE BY ADDING CALCIUM OXIDE AND CEMENT

Botla Satyanarayana
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

Eede Lakshmi Lavanya
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

Kamma Manikanta
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

Kolli Navya Sri
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

Nara Narasimha Rama Rao
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

Achanta Sudheer
UG Student, Department of Civil Engineering, Ramachandra College Of Engineering, Eluru, Andhra Pradesh, India. , IN

📅 Published: March 2019

Keywords: calcium oxide, cement, slump test and compression test, slump reduce.

📄 View / Download PDF ⬇ Download

Abstract

Concrete is versatile engineering composite material made with cement, aggregates and admixtures in some cases. Due to the day by day innovations and developments in construction fields, the usage of concrete is increase in construction. If the sometimes site has high slump problem due to that the concrete is not used because of strength problems In this study the slump content is optimised with the following materials i.e., calcium oxide and cement and combination of the CaO and cement at different proportions to increase the strength properties of concrete. Using it provides several advantages, such as improves slump and compression strength and workability properties and increase of long-term strength. The material added to concrete to reduce slump from high level to low level without loss the nomina strength of concrete for that 80 mm slump is reduced to 60mm slump value and 100mm slump is reduced to 60 mm without any change in strength of concrete.

How to Cite

Botla Satyanarayana, Eede Lakshmi Lavanya, Kamma Manikanta, Kolli Navya Sri, Nara Narasimha Rama Rao, Achanta Sudheer, “OPTIMISING THE SLUMP IN CONCRETE BY ADDING CALCIUM OXIDE AND CEMENT,” International Journal of Technical Innovation in Modern Engineering & Science, vol. 5, no. 3, pp. 462-468, March 2019.