CHARECTERIZATION OF SEWAGE AND DESIGN OF SEWAGE TREATMENT PLANT

Authors

  • S.P. Salma begum Civil department& JNTUA University
  • S. Lokesh Civil department& JNTUA University,
  • L. Chanikya Civil department& JNTUA University
  • G.S. Krupavani Civil department& JNTUA University

Keywords:

BOD, sewage, environment, design, water, pollutants, sludge etc.

Abstract

JNTU College of engineering Pulivendula is one of major educational institute in kadapa district having a large number of people residing within campus and consisting of large number of laboratories, academic blocks and number of hostels. A study on domestic waste water characterization will be performed followed by design of sewage treatment plant. The present study involves the analysis of pH value, total solids, hardness, acidity, alkalinity, chlorine content, BOD. A sewage treatment plant is quite necessary to receive domestic and commercial waste water and removes the materials which pose harm for general public and environment. The
samplings of the domestic waste from hostels have been done in Different times of the day to have an average data of the measured parameters. The average values of all parameters of sewage are found out.

Downloads

Published

2018-04-17

How to Cite

begum, S. S., Lokesh, . S., Chanikya, L., & Krupavani, G. (2018). CHARECTERIZATION OF SEWAGE AND DESIGN OF SEWAGE TREATMENT PLANT. International Journal of Technical Innovation in Modern Engineering & Science, 4(4), 151–157. Retrieved from https://ijtimes.com/index.php/ijtimes/article/view/1785